beautypg.com

Figure b figure c, Power/control wiring harness – Code 3 CPS220 Remote Strobe Power Supply User Manual

Page 5

background image

5

NOTE: IT IS IMPORTANT TO FOLLOW THE CORRECT COLOR CODE

WHEN INSERTING THE PINS INTO THE AMP 3 PIN CONNECTORS.

4. Connect the cables to the strobe light heads.

5. Next, plug the other end of the cable into one of the one of the two Light Head sockets (outputs) on the

CPS220 strobe power supply.

POWER/CONTROL WIRE HARNESS ASSEMBLY

The Power/Control wire harness assembly consists of a 3 pin AMP style connector with: 1 red, 1 black, 1

white wire (see figure C). The Power/Control wire harness assembly must be connected to the power/control

socket located on the CPS220 strobe light power supply. Use 18 gauge wire to extend the control harness

wires to a customer supplied switch to complete the installation.

IMPORTANT: To extend the

power (+) and ground (-) wires,

use the following as a guide.

1 to 10 ft. use 16AWG wire

10 to 20 ft. use 14AWG wire

20 to 30 ft. use 12AWG wire

30 to 50 ft. use 10AWG wire

SHIELD WIRE CONNECT TO

CHASSIS GROUND

Male Amp connector

to be mated with the
Amp output socket on
the Power Supply.

3

2

1

2

3

1

Amp wire harness
attached to Strobe

light head.

Female Amp

connector.

3

1

2

Insert wires with male pins into the
proper locations in the male Amp

connector:
RED WIRE - POSITION 1
BLACK WIRE - POSITION 2
WHITE WIRE - POSITION 3

FIGURE B

FIGURE C

W H I T E W I R E ( P A T T E R N S E L E C T )

R E D W I R E ( + 1 0 - 3 0 V D C )

B L A C K W I R E ( N E G A T I V E )

3

2

1

Power/Control Wiring Harness