Figure b figure c, Power/control wiring harness – Code 3 CPS220 Remote Strobe Power Supply User Manual
Page 5
5
NOTE: IT IS IMPORTANT TO FOLLOW THE CORRECT COLOR CODE
WHEN INSERTING THE PINS INTO THE AMP 3 PIN CONNECTORS.
4. Connect the cables to the strobe light heads.
5. Next, plug the other end of the cable into one of the one of the two Light Head sockets (outputs) on the
CPS220 strobe power supply.
POWER/CONTROL WIRE HARNESS ASSEMBLY
The Power/Control wire harness assembly consists of a 3 pin AMP style connector with: 1 red, 1 black, 1
white wire (see figure C). The Power/Control wire harness assembly must be connected to the power/control
socket located on the CPS220 strobe light power supply. Use 18 gauge wire to extend the control harness
wires to a customer supplied switch to complete the installation.
IMPORTANT: To extend the
power (+) and ground (-) wires,
use the following as a guide.
1 to 10 ft. use 16AWG wire
10 to 20 ft. use 14AWG wire
20 to 30 ft. use 12AWG wire
30 to 50 ft. use 10AWG wire
SHIELD WIRE CONNECT TO
CHASSIS GROUND
Male Amp connector
to be mated with the
Amp output socket on
the Power Supply.
3
2
1
2
3
1
Amp wire harness
attached to Strobe
light head.
Female Amp
connector.
3
1
2
Insert wires with male pins into the
proper locations in the male Amp
connector:
RED WIRE - POSITION 1
BLACK WIRE - POSITION 2
WHITE WIRE - POSITION 3
FIGURE B
FIGURE C
W H I T E W I R E ( P A T T E R N S E L E C T )
R E D W I R E ( + 1 0 - 3 0 V D C )
B L A C K W I R E ( N E G A T I V E )
3
2
1
Power/Control Wiring Harness