beautypg.com

Code 3 Code 360 User Manual

Page 22

background image

22

N O T E S :

PROBLEM

ArrowStik

®

does not

function when turned on

Lamp does not come on
when it should.

Right most lamp does
not come on in Arrow
Left mode or left most
lamp does not come on
in Arrow Right mode.

ArrowStik runs opposite
pattern than selected.

Lamp looks dim.

CAUSE

a. Plug in rear of control box is

loose or disconnected.

b . Poor ground connection
a . Power from battery has been

disconnected or the control
box has been damaged.

a . Lamp has burned out.
b . Bad wiring connection.

a . Control box has been

damaged.

a . Normal operation

a . Defective Wiring.

b . Control box has been

damaged.

a . Defective lamp.
b . Low voltage.
c . Poor ground
d. Product is in "Dim" mode.

SOLUTION

a. Reconnect plug.

b . Reconnect ground.
a . Check connections at the battery

and plug. If connections are good
and voltage is at least 10 volts, the
control box has been damaged.
Repair or return to Code 3

®

.

a . Replace lamp.
b . Repair connection.

a . Repair or return to Code 3.

a . N o n e

a . Check that the cable exit is on the

driver's side

b . Repair or return to Code 3.
a . Repair or return to Code 3.

a . Replace lamp.
b . Check connections or battery.
c . Check ground and wire gauge.
d . Select appropriate mode.

QUESTION

Are LED's functioning
properly?

Ye s

N o

Are LED's func-
tioning properly?

Ye s

N o

Follow the guide below for information on repair and trouble shooting for the arrowstik option.

ARROWSTIK OPTION

TROUBLESHOOTING GUIDE