Standard Protection Mechanisms
The cooling unit is programmed to shut down certain components to
protect those components, as well as the wine inside the cellar, under the
following circumstances:
Scenario
What it means
What happens
P1 Alarm
Probe 1, which senses the
temperature inside the
cellar and controls the
on/off cycles of the cooling
unit, has failed
The cooling unit enters a
timed auto-cycle mode
until Probe 1 is repaired or
replaced. In this mode, the
cooling unit will turn on for
12 minutes and off for 8
minutes.
Scenario
What it means
What happens
HA2 Alarm
P3 > 140° F
The condenser probe is
measuring temperatures
that are too hot
The compressor and
condenser fan will turn off
until the condenser
temperature falls below
120°F