Mount the unit in the upright position close to the ceiling inside the
cellar. As warm air rises to the top of the cellar, the cooling unit pulls the
warm air through the evaporator coil and removes the heat from the
warm air. Once cooled, the cold air is discharged from the front of the
cooling unit and circulates through the cellar.
Slide the unit through from the outside of the cellar.
CAUTION
: Two
people are required to move the cooling unit, which is very heavy.
Do not place the cooling unit on unprotected bottle racks.
Tilt the cooling unit slightly backwards. The rear of the cooling unit
should be slightly lower than the front of the cooling unit to facilitate the
flow of excess condensate to the drain line.
Use our adjustable mounting brackets to support and anchor the cooling
unit to the framing in the wall. Use the (16) #10x1-1/2” flat Phillips head
wood screws provided to anchor the screws into the studs and braces.
The mounting brackets can be used either inside or outside the cellar and
can be used in three different locations, as shown below.