I I . I n s t a l l a t i o n I n s t r u c t i o n s
TEST THE UNIT BEFORE INSTALLING IT
1. Remove the unit from the box. SAVE THE BOX AND PACKING
MATERIALS.
2. Plug in the power cord and let the unit run on a hard, flat surface
for no more than 5 minutes.
3. Check to make sure that both fans (one in the front and one at the
rear of the cooling unit) are blowing.
4. Check that the cooling unit is discharging cold air from the front (it
should be approximately 10 - 12° F colder than the temperature on
the digital display)
5.
Please note
: The cooling system is programmed with a 3-Minute
Delay at Startup to protect its internal components
Cut a hole in the wall that is 1/4 inch larger than the dimensions (W x
H) of the cooling unit, and create a frame to support the rear of the
cooling unit. The rear of the cooling unit should be supported by the
wall through which it is installed. Horizontal 2 x 4 inch braces should be
installed between the studs below and above the cooling unit. If the
studs in the wall must be cut to accommodate the width of the cooling
unit, vertical braces also should be installed on either side of the cooling
unit.
3200 / 4200 Frame and Cut-Out Diagram