5
I I . I n s t a l l a t i o n I n s t r u c t i o n s – W i n e C e l l a r s
Specifications
Model Dimensions
(mm)
W x D x H
Weight
(kg)
Operating
Amps
1800XT
457 x 419 x 267
27.2
2.0
Cooling Capacity*
Estimated thermal loads for various size cellars, with various insulations, various
ambient temperatures and various cellar temperatures, are shown in the table below.
To figure out whether a CellarPro unit will work in your space, make sure that the
cooling unit’s BTUH for a given cellar temperature is equal or greater than the
thermal load shown. The bold numbers are within the capacity of both units. The
unbold numbers in black are within the capacity for the 1800XT 60Hz but not for the
1800XT 50Hz. The numbers in
red
are beyond the capacity of both cooling units.
Cellar Temp
12.8 °C
15.6 °C
BTUH
1800XT 220V/50Hz
1248
1353
BTUH
1800XT 230V/60Hz
1438
1543
Cellar Insulation –
All Walls, ceiling & floor*:
R-12
R-19
R-12
R-19
Cellar Size
Ambient Temp
23.9 °C
1034 946 889 814
2.83 m
3
29.4 °C
1180 1046 1038 920
35.0 °C
1331
1153 1195 1038
23.9 °C
1313
1186 1129 1020
5.66 m
3
29.4 °C
1538
1349
1353 1187
35.0 °C
1778 1525
1500 1373
23.9 °C
1594
1435 1371 1234
8.50 m
3
29.4 °C
1900 1562 1672
1463
35.0 °C
2225 1909 2003 1718
*Please note: Glass door(s) in the wine cellar have much lower insulation values
than insulated walls, which will increase the heat load and therefore reduce the
cooling unit’s capacity.