18 troubleshooting, 1 safety notices, 2 cause and action – CASO Germany VC 10 Vacuum System User Manual
Page 40: Attention
caso Vakuumierer VC10
40
Vacuum interface:
Unbag the airproof loop of sponge from the interface and put it into warm and soapy water
for safe washing.
Please note
► The airproof loop of sponge should be dried thoroughly prior to reassembling.
► When re-assembling, be careful to prevent any damage and assembles as original
position to ensure no vacuum leaking.
18 Troubleshooting
This chapter provides you with important notices with regard to operating the device.
Observe the following notices to avoid dangers and damages:
18.1 Safety notices
Attention
► Only qualified electricians, who have been trained by the manufacturer, may carry out
any repairs on electrical equipment.
► Improperly performed repairs can cause considerable dangers for the user and
damages to the device.
18.2 Cause and Action
In the event of a fault, an error code will appear in the display; it describes the cause of the
fault.
Error
Possible cause
Rectification
Vacuum unit is not
functioning
Power plug is not plugged in
Plug in mains plug!
Defective power cable or plug Send device to Customer Service
Defective electrical socket
Select another electrical socket
The first weld on the
cut off piece of the roll
is not being carried
out.
Roll is not positioned
correctly
Follow the steps in the chapter
“Vacuum packaging in a bag
originating on the roll”
A complete vacuum is
not being created in
the bag.
The open end of the bag is
not completely inside the
vacuum chamber
Position the bag correctly
The bag is defective
Select another bag
There is dirt on the welding
and the normal seals
Clean the seals and retry
correctly once they are dry