Parameter

Setting

Default settings in bold

P1.xy

Auto shutoff timer in minutes
Set up time for the auto off function.
(00 = 0ff, 01-15 = time in minutes)

P1.00
P1.01 – P1.15,
P1.5 = 5 minutes

P2.x

Hold and print key functionality
Setup button function
0 = Press button once to activate hold
1= Press button once to print
2= Press button to print/Press and hold button to activate hold.

P2.0= Hold
P2.1= Print;
P2.2= Print & Hold,

P3.xy

Hold Function Settings
0= No hold function active.

1= Averaging hold with manual push button release.
The weight reading will be held on the display until a higher
weight is applied, this will automatically release the held weight
and re-hold it at the new higher weight reading.

2= Averaging hold with automatic release and re-hold.
As above but The weight reading will be held on the display until
the platform is empted and the next weight reading over
10divisions is applied.

3-50= Selectable hold window from +/- 3 to 50 divisions
Will hold display reading once stable within a selectable weight
range, to release the hold button must be represses..

P3.0
P3.1
P3.2
P3.3 to 50

P4.x

RS232 – Serial Interface
Settings for serial interface
0= No RS232 output

1= Print displayed data once stable when print key is pressed;

2= Print gross, tare and net weight once stable when print key is
pressed

3= Continuously output gross weight

4= Continuously output gross, tare and net weight


5= Print displayed data once stable one time only.

6= Print gross, tare and net weight once stable, one time only.

7= Bidirectional - RS232, SBI protocol

P4.0
P4.1
P4.2
P4.3
P4.4
P4.5
P4.6
P4.7

P5.x

RS232 Baud rate

P5.0= 1200 P5.3= 9600
P5.1= 2400 P5.4= 19200
P5.2= 4800

P6.x

RS232 Data format
0 = 8 bits, no parity, 1 start bit, 1 stop bit
1 = 7 bits, 1 even, 1 start bit , 1 stop bit
2 = 7 bits, 1 odd, 1 start bit, 1 stop bit

P6. 0
P6. 1
P6. 2

P7-P19 .x

SERVICE CONFIGURATIONS ONLY

Any adjustment to these settings could seriously affect the indicators performance.

Seek advice from a service engineer before changing.