beautypg.com

Configuration, User menu chart – Salter Brecknell SP100 User Manual

Page 5

background image

02/18/04

5

Configuration

All Serial Communication parameters are em-

bedded in a user menu consisting of 5 separate

menu selections, each with its own sub-menu of

choices. If your scale is connected by RS-232

serial communication lines to other equipment,

or you wish to disable the

lb/kg

key, you may

have to modify some or all of these parame-

ters. To modify these parameters, you must first

enter the USER MENU mode. Once there, four

of the front panel keys become directional navi-

gators to move around in the menus, and one

key is used to save or SET the selections. Com-

plete directions are found below.

To place the unit in USER MENU mode:

Turn the scale off.

While holding down the

lb/kg

key, turn the scale back on.
When the display shows "

A1

",

the unit is in USER MENU mode,

and you can release the

lb/kg

key. Shown at right are the

directional and SET key assign-

ments.

Zero

Gr

Net

lb

kg Motion

Tare

MODEL

SPD100

TRANSTRONIC SCALE CO.

CLASS

CAPACITY :

100x0.05 lb

50x0.02 kg

n

max=3000

SET

USER MENU CHART

A2

A3

A4

A5

A1

Baud Rate

Data Bits,

Parity

Transmission

Mode

Serial Data Format

Disable Lb/kg

Key

c

d

0

1

8

7O

7E

7

0

1

2

3

4

1200

2400

4800

9600

To place the unit back into the NORMAL OPERATING mode, turn off the power to the unit.

With no keys held down, turn the power back on. All front panel keys will now return to

their normal mode of operation.

SETTINGS FOR USE WITH UPS ONLINE AND ONLINE OFFICE SOFTWARE

A1 = 9600
A2 = 7 o
A3 = don’t care

A4 = 4
A5 = 0

This manual is related to the following products: