5.2.4 Channel Level Control

The signal level for each input can be attenu ated
accurately by adjusting the 21-step Level
Control (see Section 4.2). Figure 5.2 shows the
amount of attenuation in dB for each detent.

Note: Attenuation per detent varies with
operat ing mode since gain varies with operating
mode. Attenuation amounts shown may vary
±6%.

Detent

4/8 Ohm

70V

100V

0 (full CCW)

68.31

72.90

71.02

1

67.54

72.06

70.26

2

32.23

36.61

34.90

3

25.46

29.74

28.00

4

21.83

25.87

24.22

5

19.23

23.20

21.58

6

17.12

20.94

19.40

7

15.36

19.02

17.53

8

13.76

17.22

15.79

9

12.28

15.53

14.20

10

10.84

13.90

12.62

11

9.51

12.32

11.16

12

8.28

10.87

9.81

13

7.09

9.45

8.45

14

6.30

8.11

7.22

15

4.92

6.70

5.94

16

3.82

5.26

4.63

17

2.62

3.70

3.21

18

1.35

1.90

1.66

19

0.01

0.01

0.01

20 (full CW)

0.00

0.00

0.00

ATTENUATION in dB

Figure 5.2 Level-control Attenuation per Detent in CTs Multichannel Amplifi ers