5.3.1 Nominal Attenuation Settings

The signal level for each input can be attenuated repeatably by
adjusting the 21-step Level Control (see Section 4.3). Figure 5.5
shows the attenuation in dB for each detent. The setting of the
input-sensitivity switch varies the actual attenation as shown.

Detent

26 dB

Tolerance (dB)

4/8 ohm or 70/100V

0 (full CCW)

OFF

OFF

1

48.0

±6

54.0

2

36.0

±6

42.0

3

24.0

±3

30.0

4

21.0

±3

26.0

5

18.0

±3

24.0

6

15.0

±3

22.0

7

13.5

±3

20.0

8

12.0

±1.5

18.0

9

10.5

±1.5

16.0

10

9.0

±1.5

14.5

11

8.0

±1.5

13.0

12

7.0

±1.5

11.0

13

6.0

±1

9.5

14

5.0

±1

8.0

15

4.0

±1

6.5

16

3.0

±1

5.0

17

2.0

±1

3.5

18

1.0

±1

1.5

19

0.5

+1 –5

0.5

20 (full CW)

0.0

0.0

Figure 5.1 Level-control Attenuation per Detent for CTs 2-Channel Amplifi ers