beautypg.com

Troubleshooting – AVer PL50 user manual User Manual

Page 44

background image

ENGLISH

39

Function

Data[0]

CheckSum

Code

ReData[0]

DISPLAY STATUS

0x06

0x5E

0: CAMERA MODE

1: PLAYBACK MODE

2: PC-1 PASS THROUGH

3: PC-2 PASS THROUGH

VIDEO OUTPUT
STATUS

0x07

0x5F

0: VGA 1: TV

FREEZE STATUS

0x08

0x50

0 : OFF 1: ON

BRIGHTNESS
VALUE

0x0A

0x52

VALUE[ 0 ~ 63 ]

CONTRAST VALUE

0x0B

0x53

VALUE[ 0 ~ 255 ]

LIGHT BOX STATUS
(ONLY AVerVision
PL50)

0x0C

0x54

0 : OFF 1: ON

T

T

r

r

o

o

u

u

b

b

l

l

e

e

s

s

h

h

o

o

o

o

t

t

i

i

n

n

g

g

This section provides many useful tips on how to solve common problems while using the
AVerVision PL50.

There is no picture on the presentation screen.

1. Check all the connectors again as shown in this manual.
2. Check the on/off switch of the display output device.
3. Verify the setting of the display output device.
4. If you are presenting from a notebook or computer through the display output device, check the

cable connection from computer RGB (VGA) output to RGB input of AVerVision PL50 and make
sure AVerVision PL50 is in PC Mode.

5. For HDMI display output, a delay occurs while waiting for both the display device and AVerVision

PL50 to sync up. Wait for around 4 to 7 seconds until you see the camera image on the screen.

I have set up the AVerVision PL50 and checked all the connections as specified in
the manual but I cannot get a picture on the preferred presentation screen.

1. The unit POWER button turns orange in standby mode. Press the POWER button again to turn

on and the LED light will turn blue.

2. The default camera display resolution setting is on 1024x768. If your output device does not

support this resolution; no image can be projected. Simply press hold the FREEZE and

► button

to the change the resolution setting.

3. If your display output device is on TV or any analog device, please switch the TV-RGB dip switch

to TV.

The picture on the presentation screen is distorted or the image is blurry.

1. Reset all changed settings, if any, to the original manufacturer default setting. Press DEFAULT on

the remote or select Default in Basic tab OSD menu.

2. Use the Brightness and Contrast menu functions to reduce the distortion if applicable.
3. If you discover that the image is blurry or out of focus, press the Auto Focus button on the control

panel or remote control.