8B

8

WIDE FIXED

Position the wide fixed panel assembly on

threshold of the base (B) as shown. Adjust

the wall bracket (3) as well as the return

panel glass mount bracket (14) so as to

ensure that the running rail (1) is secured.

Ensure that the fixed panel gasket (12)

collapses against the wall properly.

Ensure that the running rail (1) is level and

that the wide fixed panel (20) is square. If

a horizontal correction is required, adjust

and level the glass holders for fixed

panel (5).

8A

20

B

The bottom guide (7) can hang off the threshold

(B) as long as it can be well-fastened.

INTERIOR

SHOWER SIDE

B

1

90

°

90°

5

1/2” max

(12.7mm)

12

20

3

20

7

20