beautypg.com

Vermont castings seville, Fig. 11 csa approved wall pass-through – Vermont Casting 1635 User Manual

Page 8

background image

8

Vermont Castings Seville

30001490

Placing a chimney connector pipe inside a section
of 9" (229mm) diameter, solid-insulated, factory-built
chimney, with two inches of air space between the
chimney section and combustibles. (Fig. 10)

Canadian Requirements:In Canada, the Canadian
Standards Association has established specific
guidelines regarding wall pass-though design. Figure
11 shows one approved method in which all
combustible material in the wall is cut away to provide
the required 18" (457mm) clearance around the
connector. The resulting space must remain empty. A
flush-mounted sheet metal cover may be used on one
side only. If covers must be used on both sides, each
cover must be mounted on noncombustible spacers at
least 1" (25mm) clear of the wall. Your local dealer or
your local building inspector can provide details of
other approved methods of passing a chimney
connector through a combustible wall.

In Canada, this type of installation must conform to
CAN/CSA-B365, Installation Code for Solid Fuel
Burning Appliances and Equipment.

Fig. 9 Wall Pass-through using single wall chimney
connector with a ventilated steel thimble.

Min. 6"
(152mm)

Chimney clearance to sheet
steel supports and combustibles

2" (51mm) Min.

Glass Fiber
Insulation

Chimney Connector

Chimney Flue

Steel Thimble
with two 1"
(25mm) Ventilated
Channels

Masonry Chimney
constructed to NFPA 211

24 ga.Sheet
Steel Supports

ST274

Fig. 10 Wall Pass-through with ventilated steel thimble.

24 ga. Sheet
Steel Supports

24 ga. Sheet
Steel Supports

2" (51mm) Min.

Chimney clearance to sheet steel
supports and combustibles

2" (51mm)
Min.

Chimney Flue

2" (51mm) Min.
air space

Prefab
Chimney
Section

Prefab
Chimney
Section

Chimney

Connector

Masonry Chimney
constructed to NFPA 211

ST275

Fig. 11 CSA approved Wall Pass-through.

24 ga.Sheet
Steel Support

24 ga. Sheet
Steel Support
(one side only)

Min. 18"
(460mm)

Chimney clearance to sheet steel
supports and combustibles

2" (51mm)

Min.

Chimney Flue

Chimney
Connector

Masonry Chimney
constructed to CAN/CSA-
B365

Min. 18"

(460mm)

ST276

This manual is related to the following products: