beautypg.com

Adjusting the transparent sensor – Citizen Systems Citizen CL-S700 User Manual

Page 47

background image

47

Printer Adjustments

Adjusting the Transparent sensor

1. The transparent sensor is selected.
2. Install only the liner media (label backing paper) with the label

media removed so that it will pass between the platen roller and
the media sensor. (Be careful that media with black marks does
not pass the media sensor.) Then close the sensor arm and the
printhead.

Installing the Media (p.24)
Quick Sensor Selection
Method
(Transparent

↔ Reflective)

(p.46)

Sensor Adjustments and Calibration

3. If the Pause Key is pressed then released while the MENU key is

continually pressed, the sensor is automatically adjusted.

Sensor Cal Mode

Executing

4. When automatic adjustment stops normally, “Succeeded” is

displayed by the LCD. If it stops abnormally (adjustment is
impossible), ERROR LED flashes and “Failed” is displayed on
the LCD.

Sensor Cal Mode

Succeeded

5. If the STOP key is pressed, the Printer completes sensor

adjustment and the printer restarts.

Label

Media gap

Bottom sensor

Upper sensor

Liner media

MENU

PAUSE

Hold

Press/Release