Adjusting the transparent sensor – Citizen Systems Citizen CL-S700 User Manual
Page 47
47
Printer Adjustments
Adjusting the Transparent sensor
1. The transparent sensor is selected.
2. Install only the liner media (label backing paper) with the label
media removed so that it will pass between the platen roller and
the media sensor. (Be careful that media with black marks does
not pass the media sensor.) Then close the sensor arm and the
printhead.
Installing the Media (p.24)
Quick Sensor Selection
Method
(Transparent
Sensor Adjustments and Calibration
3. If the Pause Key is pressed then released while the MENU key is
continually pressed, the sensor is automatically adjusted.
Sensor Cal Mode
Executing
4. When automatic adjustment stops normally, “Succeeded” is
displayed by the LCD. If it stops abnormally (adjustment is
impossible), ERROR LED flashes and “Failed” is displayed on
the LCD.
Sensor Cal Mode
Succeeded
5. If the STOP key is pressed, the Printer completes sensor
adjustment and the printer restarts.
Label
Media gap
Bottom sensor
Upper sensor
Liner media
MENU
PAUSE
Hold
Press/Release