Error Messages
Message
Cause(s)
Action(s)
Lamp Startup Fail
The lamp has not started after being
struck.
• Check lamp
• Check lamp socket and wiring
• Check ballast and igniter
Temperature Sense Fail
There is no communication with
temperature sensor.
• Check sensor wiring
• Check sensor integrity
• Check control board
Lamp Hot Protection
Fixture temperature is higher than 105º C;
lamp was switched to low power for safety.
• Check fans
• Check fan wiring
• Clean vents
Lamp Hot Power Off
Fixture temperature is 110º C or higher;
lamp was switched to off for safety.
• Check fans
• Check fan wiring
• Clean vents
Maintenance Fixture
Fixture Maintenance timer expired.
• Proceed with maintenance and reset timer
Lamp On Over 700 Hour Lamp change is overdue.
• Change lamp
Memory Initial Fail
Memory chip error found.
• Change main board
Fan 1 Error
Fan 2 Error
Fan 3 Error
Fan 4 Error
Fan 5 Error
Fan 6 Error
The indicated fan is not working.
• Check fan
• Check fan wiring
CPU-B Error
CPU-C Error
CPU-D Error
CPU-E Error
CPU F Error
CPU G Error
There is no communication with the
indicated auxiliary CPU.
• Check sensors wiring and position
• Check stepper motor, belt, and driver board
• Check control boards
Pan Home Sensor Error
Pan Encode Error
Tilt Home Sensor Error
Tilt Encode Error
The moving head failed going to home
position after power up or fixture reset.
• Check moving head’s free movement
• Check sensors’ wiring and position
• Check stepper motor, belt ,and driver board
• Check the corresponding control board
• Check main control board
Shutter Reset Fail
Dimmer Reset Fail
Color 1 Reset Fail
Color 2 Reset
Cyan Reset Fail
Magenta Reset Fail
Yellow Reset Fail
3200 K Filter Reset Error
Frost Reset Fail
Zoom Reset Fail
The indicated moving part failed going to
home position after power up or fixture
reset.
• Check part’s free movement and integrity
• Check sensors’ wiring and position
• Check stepper motor, belt, and driver board
• Check the corresponding control board
• Check main control board