Specifications – Taylor-Wharton XL-65HP (with dual regulators) User Manual
Page 3
![background image](/manuals/628260/3/background.png)
XL-65
XL-65HP
Dimensions
Diameter
26 in. (660 mm)
26 in. (660 mm)
Height*
59 1/4 (1505 mm)
59 1/4 (1505 mm)
Weight, Empty
5 Caster Base
375 lb. (170 kg)
465 lb. (211 kg)
4 Caster Base
445 lb. (202 kg)
535 lb. (243 kg)
Capacity, Gross
250 liters
247 liters
Capacity, Usable Liquid
240 liters
240 liters
Weight of Contents Maximum
Based on DOT Relief Valve Setting
Carbon Dioxide
N/A
516 lb. (234 kg)
Oxygen
539 lb. (176 kg)
505 lb. (229 kg)
Nitrogen
380 lb. (172 kg)
353 lb. (160 kg)
Argon
655 lb. (297 kg)
614 lb. (279 kg)
Nitrous Oxide
N/A
543 lb. (246 kg)
Normal Evaporation Rate**
(% Capacity per Day)
Carbon Dioxide
N/A
0.75%
Oxygen
1.0%
1.0%
Nitrogen
1.6%
1.6%
Argon
1.0%
1.0%
Nitrous Oxide
N/A
0.75%
Gas Flow Rate @ NTP (@ STP)
Carbon Dioxide
N/A
150 cfh (3.9 cu.m/h)
Oxygen, Nitrogen, Argon
350 cfh (9.2 cu.m/h)
350 cfh (9.2 cu.m/h)
Nitrous Oxide
N/A
110 cfh (2.9 cu.m/h)
Relief Valve Setting
230 psig
350 psig
(16 bar/1586 kPa)
(24 bar/2413 kPa)
Inner Container Bursting Disc
380 psig
525 psig
(26 bar/2620 kPa)
(36 bar/3620 kPa)
Dual Pressure Building/
Economizer Regulator***
Pressure Building Setting
125 psig
300 psig
(8.6 bar/862 kPa)
(20.7 bar/2069 kPa)
Economizer Setting
145 psig
320 psig
(10 bar/1000 kPa)
(22 bar/2206 kPa)
Design Specifications
TC/DOT
4LM/4L
4LM/4L
Gaseous Capacity
Based on DOT Relief Valve
Setting @ NPT (STP)
Carbon Dioxide
N/A
4511 cu.ft. (119 cu.m)
Oxygen
6511 cu.ft. (171 cu.m)
6100 cu.ft. (160 cu.m)
Nitrogen
5244 cu.ft. (138 cu.m)
4871 cu.ft. (128 cu.m)
Argon
6335 cu.ft. (166 cu.m)
5938 cu.ft. (156 cu.m)
Nitrous Oxide
N/A
5419 cu.ft. (142 cu.m)
Specifications subject to change without notice.
* 5 Caster base used for height measure; for 4 Caster square base with handle add approximately 1/2 in. (12.7 mm)
* 8 Vented N.E.R. based on Useable Liquid Capacity.
***Regulator has a pressure delta of 20 psig (1.4 bar/138 kPa).
SPECIFICATIONS