20

Models 750, 751, 754, 774, 794

Operating Procedures

Install the air orifice into the hole in the top of the air

tube (in the end without the small hole on the side).

Figure 21

Step 11

Lay the air tube (with the air orifice installed) and the

hopper gasket in the bottom of the mix hopper for

sanitizing.

Note: The Models 754 and 774 have one hopper

gasket for each mix hopper. The Model 794 does not

require a hopper gasket.

Repeat steps 10 and 11 for the other side of the

freezer on Models 754, 774 and 794.

Sanitizing

Step 1

Prepare two gallons (7.6 liters) of an approved 100

PPM sanitizing solution (example: Kay-5r). USE

WARM WATER AND FOLLOW THE MANUFACTUR-

ER’S SPECIFICATIONS.

Step 2

Pour the two gallons (7.6 liters) of sanitizing solution

into the hopper and allow it to flow into the freezing

cylinder.

Figure 22

Step 3

While the solution is flowing into the freezing cylinder,

brush clean the mix hopper. When cleaning the

hopper, take particular care in brushing the mix level

sensing probe on the rear wall of the hopper, the mix

inlet hole, the air tube, and the hopper gasket.

Figure 23

Figure 24