Important: To the Operator

Reset Button

On counter models, the reset button is located on the

side of the unit. On console models, the reset button

is located in the service panel. The reset protects the

beater motor from an overload condition. If an overload

occurs, the reset mechanism will trip. To properly reset

the freezer, press the AUTO key to cancel the cycle.

Turn the power switch to the OFF position. Press the

reset button firmly.

Do not use metal objects to press the reset

button. Failure to follow this instruction may

result in electrocution.

Turn the power switch to the ON position. Press the

WASH key and observe the freezer’s performance.

Open the side access panel. Make sure the beater

motor is turning the drive shaft in a clockwise direction

(from the operator end) without binding.

If the beater motor is turning properly, press the WASH

key to cancel the cycle. Press the AUTO key to resume

normal operation. If the freezer shuts down again,

contact a service technician. (For Models 754, 774,

and 794 press the AUTO key on both sides of the unit

to resume normal operation.)

Air Tube

The air tube serves two purposes. One end of the tube

has a hole and the other end does not.

Figure 1

1. After priming the machine, lubricate the o-rings

on the air tube (the end with the hole) and

place it into the mix inlet hole. Every time the

draw handle is raised, new mix and air from the

hopper will flow down into the freezing cylinder.

This will keep the freezing cylinder properly

loaded and will maintain overrun.

2. During long “No Sale” periods, remove the air

orifice. Lubricate the o-rings on the air tube (the

end without the hole), and place it into the

mix inlet hole. This will prevent any mix from

entering the freezing cylinder.

The air orifice is used to meter a certain amount

of air into the freezing cylinder. The air orifice

maintains overrun and allows enough mix to enter

the freezing cylinder after a draw.

Adjustable Draw Handle

These units feature an adjustable draw handle to

provide the best portion control. The draw handle

should be adjusted to provide a flow rate of 5 to 7-1/2

oz. (148 to 222 ml) of product per 10 seconds. To

INCREASE

the flow rate,

turn the screw

COUNTERCLOCKWISE.

Turn

the

screw

CLOCKWISE to DECREASE the flow rate. During

“Sanitizing” and “Rinsing”, the flow rate can be

increased by removing the pivot pin and placing the

restrictive bar on the TOP. When drawing product,

always place the restrictive bar on the bottom.

Figure 2

IMPORTANT: Once the draw rate is set, tighten the

lock nut with a wrench.