Password recovery - option[3, Set terminal baud-rate - option[4, Software download – Dell PowerEdge VRTX User Manual
Page 24

24
Using the CLI
FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\Maintenance Projects\Dell
Plasma\GSG\Plasma_UGUsing_CLI.fm
D E L L C O N F ID E N T IA L – P R E L IM I N A RY 3 / 6 /1 3 - FO R P R O O F O N LY
3 Enter config ("config" is the standard name for the Startup configuration
file although you can use any name).
The following is displayed:
The configuration is erased when the system is reset.
Password Recovery - Option[3]
If a password is lost, the Password Recovery procedure can be called from the
Startup menu. The procedure enables entry to the device a single time
without entering a password.
To recover a lost password when entering the local terminal only:
1 From the Startup menu, select
[3]
.
2 Continue the regular startup by logging in without a password.
3 Enter a new password or press 'ESC' to exit.
NOTE:
To ensure device security, reconfigure passwords for applicable
management methods.
Set Terminal Baud-Rate - Option[4]
To set the terminal baud-rate:
1 Type
[4]
and press
2 Enter the new baud rate. The following is displayed:
Note that after this step, your terminal will no longer respond. Adjust your
terminal speed to the configured one.
Software Download
This section contains instructions for downloading device software (system
and boot images) through a TFTP server. The TFTP server must be
configured before downloading the software.
File config (if present) will be erased after system initialization
======== Press Enter To Continue ========
Set new device baud-rate: 38,400