beautypg.com

Mode select 10 (55h), Mode, Select – Dell PowerVault TL4000 User Manual

Page 43: 55h)

background image

MODE

SELECT

10

(55h)

The

MODE

SELECT

(10)

command

provides

a

means

for

the

host

to

specify

peripheral

device

parameters

to

the

media

changer.

Application

clients

should

issue

MODE

SENSE

prior

to

each

MODE

SELECT

to

determine

supported

pages,

page

lengths,

changeable

variables

and

to

determine

is

the

page

is

savable

to

NVRAM.

For

documentation

on

the

supported

Mode

Select

pages

refer

to

the

Mode

Select

(6)

description.

Bit

7

6

5

4

3

2

1

0

Byte

0

Operation

Code

(55h)

1

LUN

PF

(1)

Reserved

SP

2

Reserved

3

Reserved

4

Reserved

5

Reserved

6

Reserved

7

IMSB)

Parameter

list

length

8

(LSB)

9

Control

Field

descriptions:

PF:

A

PF

bit

of

one

indicates

that

the

MODE

SELECT

parameters

following

the

header

and

block

descriptor(s)

complies

with

the

SCSI-2

specification.

The

value

must

be

set

to

1.

SP:

A

Save

Pages

(SP)

bit

of

zero

indicates

the

media

changer

shall

perform

the

specified

MODE

SELECT

operation,

and

shall

not

save

any

pages

in

non

volatile

ram.

An

SP

bit

of

one

indicates

that

the

media

changer

shall

perform

the

specified

MODE

SELECT

operation,

and

shall

save

the

current

values

to

a

non

volatile

RAM.

Chapter

3.

Supported

SCSI

Commands

3-29