Dell PowerEdge M610x User Manual
Page 123
About Your System
123
DIMMs
disabled - MemBIST
error.
The memory modules are
not properly seated.
The memory module
connector may be exposed
to dust.
Unsupported memory
module.
Replace or reseat the
memory module(s). See
page 171.
Ensure that the memory
module connectors are clean
and supported memory
modules are installed in a
valid configuration. See
DIMMs
disabled - MemBIST
timeout.
DIMMs
disabled - Rank
not found.
DIMMs
disabled - DIMM
communication
error.
DIMMs
disabled - DDR
training error.
DIMMs
disabled - Simple
memory test
failure.
DIMMs
disabled - No
memory detected.
The memory modules are
not properly seated.
The memory module
connectors may be
exposed to dust.
Unsupported memory
module.
Replace or reseat the
memory module(s). See
page 171.
Verify that the memory
modules are identical and in
a lock-step pair.
DIMMs
disabled - Invalid
DIMM.
Unsupported memory
modules in the first locked
step pair.
M910" on page 179.
Replace the memory
modules. See "System
Table 1-27. Blade Messages
(continued)
Message
Causes
Corrective Actions