Step 2: Configure the iSCSI Ports on the Storage

Array

By default, the iSCSI ports on the storage array are set to the following IPv4

settings:
Controller 0, Port 0: IP: 192.168.130.101 Subnet Mask:
255.255.255.0 Port: 3260

Controller 0, Port 1: IP: 192.168.131.101 Subnet Mask:
255.255.255.0 Port: 3260

Controller 0, Port 2: IP: 192.168.132.101 Subnet Mask:
255.255.255.0 Port: 3260

Controller 0, Port 3: IP: 192.168.133.101 Subnet Mask:
255.255.255.0 Port: 3260

Controller 1, Port 0: IP: 192.168.130.102 Subnet Mask:
255.255.255.0 Port: 3260

Controller 1, Port 1: IP: 192.168.131.102 Subnet Mask:
255.255.255.0 Port: 3260

Table B-2. Initial Setup Tasks Dialog Box

Task

Purpose

Rename the storage array

To provide a more meaningful name than the

software-assigned label, Unnamed.

Set a storage array password

To restrict unauthorized access. MDSM may ask

for a password before changing the

configuration or performing a destructive

operation.

Set up alert notifications
Set up e-mail alerts
Set up SNMP alerts

To notify individuals (by e-mail) and/or storage

enterprise management consoles, such as Dell

Management Console, (by SNMP) when a

storage array component degrades or fails, or an

adverse environmental condition occurs.

Configure a storage array

To create virtual disks and map them to hosts.

book.book Page 57 Thursday, July 18, 2013 5:56 PM