Drive not ready

Diskette missing or
improperly inserted in
diskette drive.

Reinsert or replace the diskette.

Embedded RAID error

An error has been
generated by the firmware
used by the optional
integrated RAID controller.

Update the RAID firmware using the Dell Support website at
support.dell.com.

Embedded RAID firmware is not present

The firmware used by the
optional integrated RAID
controller is not responding
to system requests.

Restore the RAID firmware using the Dell Support website at
support.dell.com.

Error: Incorrect memory configuration. Ensure

memory in slots DIMM_1A and DIMM_1B, DIMM_2A

and DIMM_2B on each memory card match

identically in size, speed, and rank.

One or more unmatched
pairs of memory modules
are detected

Ensure that the memory modules are installed in matched pairs. See
"

General Memory Module Installation Guidelines

" in "Installing System

Components."

Error: Incorrect memory configuration. When

mixing Dual and Single Rank memory on the same

memory card, Dual Rank DIMMs must be in slots

DIMM_1A and DIMM_1B, and Single Rank DIMMs must

be in slots DIMM2_A and DIMM2_B.

Dual-rank memory modules
are installed in slots
DIMM2_A and DIMM2_B.

Ensure that only single-rank memory modules are installed in slots
DIMM2_A and DIMM2_B. See "

General Memory Module Installation

Guidelines

" in "Installing System Components."

Error: Incorrect memory configuration. Memory

cards with DIMMs must be populated in order:

MEM A, MEM B, MEM C, then MEM D.

Memory riser cards must be
installed in consecutive
order.

Move memory riser cards so they are installed in order. See "

System

Memory

" in "Installing System Components."

Error: More than one RAC detected, system

halted.

Two RACs are installed, or
faulty or improperly
installed RAC.

Ensure that only one RAC is installed. Ensure that the RAC is properly
installed. See "

Troubleshooting Expansion Cards

" in "Troubleshooting

Your System."

Error: Remote Access Card initialization

failure.

Faulty or improperly
installed RAC.

Ensure that the RAC is properly installed. See "

Troubleshooting

Expansion Cards

" in "Troubleshooting Your System."

Error 8602: Auxiliary device failure. Verify

that the keyboard and mouse are securely

attached to correct connectors.

Loose or improperly
connected mouse or
keyboard cable; faulty
mouse or keyboard.

Replace the mouse. If the problem persists, replace the keyboard.

Gate A20 failure

Faulty keyboard controller
(faulty system board).

See "

Getting Help

."

General failure

Operating system
corrupted or improperly
installed.

Reinstall the operating system.

Keyboard controller failure

Faulty keyboard controller
(faulty system board).

See "

Getting Help

"

Keyboard data line failure

Keyboard failure

Keyboard stuck key failure

Loose or improperly
connected keyboard cable;
faulty keyboard; faulty
keyboard controller.

Ensure that the keyboard is properly connected. If the problem persists,
replace the keyboard. If the problem persists, see "

Getting Help

."

 

Keyboard fuse has failed.

Keyboard fuse has failed.

Replace the keyboard.

Faulty system board. See "

Getting Help

."

Manufacturing mode detected

System is incorrectly
configured.

After the message appears during system boot, press to turn
off manufacturing mode.

Memory address line failure at address, read

value expecting value

Memory double word logic failure at address,

read value expecting value

Memory odd/even logic failure at start address

to end address

Memory write/read failure at address, read

value expecting value

Faulty or improperly
installed memory modules,
or faulty system board.

Ensure that all memory modules are properly installed. See
"

Troubleshooting System Memory

" in "Troubleshooting Your System." If

the problem persists, see "

Getting Help

."

Memory mirroring enabled

Memory mirroring enabled

You can enable memory mirroring using the System Setup program if the
memory is configured to support mirroring. For more information, see
"

General Memory Module Installation Guidelines

" in "Installing System

Components," and "Using the System Setup Program" in your User's
Guide
.

Memory tests terminated by keystroke

The spacebar was pressed
during POST to terminate
the memory test.

Information only.

No boot device available

Faulty or missing diskette
drive, optical drive, or hard
drive.

 

Check the Integrated Devices configuration settings in the System
Setup program. See "Using the System Setup Program" in your User's
Guide
. Ensure that either SCSI Controller, Diskette Controller, or IDE
CD-ROM Controller
is enabled. If the system is booting from a SCSI
controller, ensure that the controller is properly connected. If the
problem persists, replace the drive. See "

Installing Drives

."

No boot sector on hard-disk drive

An operating system is not
on the hard drive.

Check the hard-drive configuration settings in the System Setup
program. See "Using the System Setup Program" in your User's Guide.

No timer tick interrupt

Faulty system board.

See "

Getting Help

."

Not a boot diskette

Not a bootable diskette.

Use a bootable diskette.

PCI BIOS failed to install

Loose cables to expansion
card(s); faulty or improperly

Ensure that all appropriate cables are securely connected to the
expansion cards. See "

Troubleshooting Expansion Cards

," in