Quadport Capable Hardware for the M1000e Modular Chassis
Page 11
Half Height Blade IO to IOM mapping
Mapping for quadport components in half height blades uses the following formulas:
(“N” being the slot the blade is installed into; 1-8. P = The internal Port Number)
“Mezz1-FAB_C”, port one and two: “P = N” (Internal Port number = Blade Slot number)
“Mezz1-FAB_C”, port three and four: “P = N+16” (Internal port number = Blade slot number + 16)
“Mezz2-Fab_B”, port one and two: “P = N” (Internal Port number = Blade Slot number)
“Mezz2-Fab_B”, port three and four: “P = N+16” (Internal port number = Blade slot number + 16
Example:
Half height blade installed in chassis slot one, a Quadport Mezzanine card in “Mezz2-Fab_B”
• “Mezz2-Fab_B” port 1 maps to IOM B1, port 1
• “Mezz2-Fab_B” port 2 maps to IOM B2, port 1
• “Mezz2-Fab_B” port 3 maps to IOM B1 port 17
• “Mezz2-Fab_B” port 4 maps to IOM B2 port 17
Figure 10 shows the physical mapping of the ports for a Half height blade installed in chassis slot 1 and a Quadport
Mezzanine card installed in Mezz2-Fab_B. The ports illustrated on the IOM are incoming ports, not external uplink
ports.