Table 1-5. Blinking Fault LED Conditions

Index

Sensor Name

Event Triggers

1

CPU0_Temp,

• Upper Critical Going High.
• Upper Non-Critical Going High.

Ambient0_Temp,
DIMM Local Temp,
Rear Temp 1
Rear Temp 2
Rear Temp 3

2

BMC Watchdog

• Time expired
• Hard reset
• Power down
• Power cycle

3

Processor

Thermal trip

4

BMC SEL

• SEL almost full
• SEL Full

5

Processor Hot

State Asserted

6

POST Error

System firmware error

7

Critical Interrupt

PCI SERR

8

DIMM-A0

• Correctable error
• Uncorrectable error
• Correctable ECC error logging limit reached

DIMM-B0
DIMM-A1
DIMM-B1

9

SYS FAN 1 ~

SYS FAN 8

• Lower critical going low
• Lower non-critical going low

10

PSU 1 Status
PSU 2 Status

• Presence detected
• TEMPERATURE Failure detected
• IOUT Failure detected
• VOUT Failure detected
• FANS Failure detected
• INPUT Failure detected