beautypg.com

Front panel user interface, Power button, Leds – Dell PowerEdge C5125 User Manual

Page 13

background image

13

Front Panel User Interface

The BMC provides control panel interface functionality including indicators

(fault, status, and ID LEDs) and buttons (power/ID).

Power Button

The power button turns the device on and off.

The power button has a deferred mechanism. When the DC is off the power button

ignores one (1) second or less activation to protect against accidental DC power on.

LEDs

BMC Heartbeat LED

The green LED provides an easy way to indicate that BMC is now enabled.

ID LED

A blinking LED indicates the Chassis Identify command has been accepted.

System Status LED

There is a dual-color LED to show the system status. The BMC turns the

LED off after all event logs are cleared.
The behavior of Status LED and ID LED is listed in Table 1-2.

Table 1-4. LED Status

LED

Color Status

Occurence

Note

Status LED Amber Blinking See "Blinking Fault

LED Conditions" on

page 15.

Off

Normal status

Green Solid On Power On (S1/S0)

The power LED status is

controlled by the BIOS.

Off

Power Off (S4/S5)