Dell Latitude C640 User Manual
Page 58

Diskette subsystem reset failed -
The floppy drive controller may be faulty. Run the
Diskette tests as described in "
Using the Dell Diagnostics
."
Diskette write-protected -
Because the floppy disk is write-protected, the operation
cannot be completed. Slide the write-protect notch.
Drive not ready -
The operation requires a floppy disk in the drive or a hard drive in
the bay before it can continue. Insert a floppy disk, or push the floppy disk all the way
into the drive until the eject button pops out. Or,
install a hard drive
in the hard drive
bay.
Error reading PCMCIA card -
The computer cannot identify the PC Card.
Reinsert the
card
or try another PC Card.
Extended memory size has changed -
The amount of memory recorded in NVRAM
does not match the memory installed in the computer. Restart the computer. If the
error appears again,
contact Dell
.
Gate A20 failure -
A memory module may be loose.
Reinstall the memory modules
and, if necessary, replace them.
General failure -
The operating system is unable to carry out the command. The
message is usually followed by specific information-for example, Printer out of
paper
. Take the appropriate action.
Hard-disk drive configuration error -
The computer cannot identify the drive type.
Turn off the computer,
remove the hard drive
, and boot the computer from a bootable
floppy disk or CD. Then turn off the computer, reinstall the hard drive, and restart the
computer. Run the Hard-Disk Drive tests as described in "
Using the Dell Diagnostics
."
Hard-disk drive controller failure 0 -
The hard drive does not respond to commands
from the computer. Turn off the computer,
remove the hard drive
, and boot the
computer from a bootable floppy disk or CD. Then turn off the computer, reinstall the
hard drive, and restart the computer. If the problem persists, try another drive. Run
the Hard-Disk Drive tests as described in "
Using the Dell Diagnostics
."
Hard-disk drive failure -
The hard drive does not respond to commands from the
computer. Turn off the computer,
remove the hard drive
, and boot the computer from
a bootable floppy disk or CD. Then turn off the computer, reinstall the hard drive, and
restart the computer. If the problem persists, try another drive. Run the Hard-Disk
Drive tests as described in "
Using the Dell Diagnostics
."
Hard-disk drive read failure -
The hard drive may be defective. Turn off the computer,
remove the hard drive
, and boot the computer from a bootable floppy disk or CD. Then
turn off the computer, reinstall the hard drive, and restart the computer. If the
problem persists, try another drive. Run the Hard-Disk Drive tests as described in
"
Using the Dell Diagnostics
."