Dell PowerVault MD3820f User Manual
Page 10

10
The number of Remote Replicas is limited to:
maximum of 32 per array
N/A
Table 4. MD-Series Storage Array Rules for Dense, 4U Models Only (MD3460,
MD3860i, and MD3860f)
MD3460
series
MD3860i
series
MD3860f
series
RULE
12Gbps
SAS
10Gbps
iSCSI
16Gbps
Fibre
Channel
Support for up to 180 physical slots with a premium feature
activation.
Maximum number of physical disks in a RAID0, RAID1/10 is 120.
Up to two MD3060e series expansion enclosures can be
attached to MD3460/MD3860i/MD3860f dense storage arrays for
a total of 3 MD3x60 enclosures.
Support for up to 120 physical slots (system default
configuration).
A minimum of 20 SAS or SSD drives are required in each MD3x60
enclosure (4 in front slots of each drawer)
Support for up to 25 SSD’s.
Default IPv4 settings for the Management Ports on the
MD Series Storage Arrays
NOTE: No default gateway is set.
By default, the management ports on the storage array are set to DHCP. If DHCP fails, the
following IPv4 settings will be used:
Table 5. Default IPv4 Management Port Addresses
Controller/Port
IPv4 address
Subnet Mask
Controller 0, Port 0
192.168.128.101
255.255.255.0
Controller 1, Port 0
192.168.128.102
255.255.255.0