Dell PowerEdge FX2/FX2s User Manual
Page 7

| 7
If A: is specified in the command, the Dell Networking OS version present in Management unit’s A: partition will be pushed.
Dell# upgrade system stack-unit 0 A:
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!
Image upgraded to all
Dell#
4.
Verify the Dell Networking OS has been
upgraded correctly in the upgraded flash
partition.
show boot system stack unit [0-5 | all]
EXEC Privilege
The Dell Networking OS versions present in A: and B: can be viewed for individual units by specifying the
stack unit id
[0-5] in the command.
Dell# show boot system stack-unit 0
Current system image information in the system:
===============================================
Type Boot Type A B
----------------------------------------------------------------
Stack-unit 0 FLASH BOOT 9.6(0.0) 9.3(0.0)[boot]
Dell#
5.
Upgrade the FN I/O Aggregator Boot
Flash and Boot Selector image.
upgrade boot [all | bootflash-image |
bootselector-image] stack-unit [0-5 | all]
[booted | flash: | ftp: | scp: | tftp: | usbflash:]
[A: | B:]
EXEC Privilege