Dell POWERVAULT MD3600I User Manual
Page 21
Getting Started With Your System
19
RAID controller module
Eight single-color LEDs:
• One battery fault
• One cache active
• One controller fault
• One controller power
• One system identification
• One management Ethernet activity
• Two iSCSI IN port activity
Four two-color LEDs:
• Two iSCSI IN link speed
• One SAS OUT link or fault
• One management Ethernet link speed
Switch
System identification button
Located on the front control panel.
This button is used to locate a system
within a rack.
Enclosure mode switch
Located on the front of the system.
This switch is not applicable to the
PowerVault MD3600i series storage array.
Password reset switch
Located on the back panel of the RAID
controller module. This switch is used to
reset the storage array password.
Power Supplies
AC power supply (per power supply)
Wattage
600 W
Voltage
100–240 VAC (8.6 A–4.3 A)
Heat dissipation
100 W
Maximum inrush current
Under typical line conditions and over the
entire system ambient operating range,
the inrush current may reach a maximum of
55 A per power supply for 10 ms or less.
LED Indicators (continued)