Water quality requirement – Cleveland Range SteamCub 1SCEMCS User Manual
Page 2

(NOT TO SCALE)
SECT.
I
PAGE
2
0707
Litho in U.S.A.
17.434"
443mm
21.625"
549mm
23.100"
587mm
25.361"
644mm
2.100"
53mm
24.858"
631mm
1.574"
40mm
30.890"
785mm
1.500"
38mm
RIGHT
SIDE VIEW
FRONT
VIEW
REAR
VIEW
Note: Consult local authorities for venting and installation requirements.
∗
For supply connection use only copper wire suitable for at least 75°C (167°F).
•
Compartment has capacity for:
Five, 12˝ x 20˝ x 2
1
⁄
2
˝ deep Cafeteria Pans.
WATER QUALITY REQUIREMENT
The recommended minimum water quality standards whether
untreated or pre-treated, based upon 10 hours of use per day,
and a Daily Blowdown, are as follows:
TOTAL DISSOLVED SOLIDS less than 60 parts per million
TOTAL ALKALINITY
less than 20 parts per million
SILICA
less than 13 parts per million
pH FACTOR
greater than 7.5
CHLORINE
less than 30 parts per million
Consult a local water treatment specialist for an on site water
analysis for recommendations concerning steam generator
feed water treatment (if required), in order to remove or
reduce harmful concentrations of minerals. The use of high-
ly mineralized water will mean that more frequent servicing of
the steam generator will be necessary. The fact that a water
supply is potable is not proof that it will be suitable for the
generator.
NOTES:
Cleveland Range reserves right of design improvement or modification, as warranted.
Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.
Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are U.L/NSF#4 and CSA (AGA, CGA).
H
D
C
C1 C2
ELECTRICAL
WATTS
VOLTS
PHASE
WIRES
CYCLE
AMPS
SUPPLY CONNECTION
HERTZ
WIRE SIZE (COPPER)*
Standard Wattage
Three Phase - 9 kW Standard
9400
208
3
3
60
26.1
10
9400
240
3
3
60
22.6
10
9400
480
3
3
60
11.4
14
Optional Low Wattage
Three Phase - 6 kW option
6400
208
3
3
60
17.8
12
6400
240
3
3
60
15.4
12
6400
480
3
3
60
7.7
14
*
For supply connection use only copper wire suitable for at least 75˚C. (167˚F).
WATTS
VOLTS
PHASE
WIRES
CYCLE
AMPS
SUPPLY CONNECTION
HERTZ
WIRE SIZE (COPPER)*
Standard Wattage
Single Phase - 9 kW Standard
9400
208
1
2
60
45.2
6
9400
240
1
2
60
39.2
8
Optional Low Wattage
Single Phase - 6 kW option
6400
208
1
2
60
30.8
8
6400
240
1
2
60
26.7
10