beautypg.com

Connecting connector, Function of each connector pins – Citizen Systems CBM-290 User Manual

Page 24

background image

CITIZEN

24

5. Connecting connector

Configuration of the connector for power and interface which is packed in this box is as follows.
Make sure to confirm the following configuration before connecting the connector.

5.1 Function of each connector pins

PIN NO. SIGNAL NAME I/O

FUNCTION

1 – 3 VCC

OUTPUT POWER SUPPLY FOR CIRCUIT (+5V)

4 – 6 GND

GND

7 – 12 VP

INPUT

POWER SUPPLY FOR OPERATION(+24V)

13 – 18 P-GND

GND FOR OPERATION

19

-

Not available

20


ERROR

OUTPUT ERROR LED OUTPUT (Can be connected directly.)

21

Not available

22 DTR

OUTPUT SERIAL INTERFACE DTR

23 TXD

OUTPUT SERIAL INTERFACE TXD

24 RXD

INPUT

SERIAL INTERFACE RXD

25 DSR

INPUT

SERIAL INTERFACE DSR

26


STB

INPUT

PARALLEL INTERFACE STROBE

27 BUSY

OUTPUT PARALLEL INTERFACE BUSY

28


ACK

OUTPUT PARALLEL INTERFACE ACK

29 DATA 0

INPUT

PARALLEL INTERFACE DATA 0

30 DATA 1

INPUT

PARALLEL INTERFACE DATA 1

31 DATA 2

INPUT

PARALLEL INTERFACE DATA 2

32 DATA 3

INPUT

PARALLEL INTERFACE DATA 3

33 DATA 4

INPUT

PARALLEL INTERFACE DATA 4

34 DATA 5

INPUT

PARALLEL INTERFACE DATA 5

35 DATA 6

INPUT

PARALLEL INTERFACE DATA 6

36 DATA 7

INPUT

PARALLEL INTERFACE DATA 7

37 PE

OUTPUT PARALLEL INTERFACE PE

38


FAULT

OUTPUT PARALLEL INTERFACE FAULT

39


RESET

INPUT

PARALLEL INTERFACE RESET

40

-

-

Not available

Using connector : LY20-40P-DT1-P5 (JAE) or equivalent

Applicable connector : LY10-DC40 (JAE) or equivalent

This manual is related to the following products: