beautypg.com

Troubleshooting, Safety opera tion maintenance setup – Harbor Freight Tools Chicago 91938 User Manual

Page 13

background image

Page 13

For technical questions, please call 1-800-444-3353.

SKU 91938

SAFETY

OPERA

TION

MAINTENANCE

SETUP

Troubleshooting

Problem

Possible Causes

Likely Solutions

Tool will not start.

1. Cord not connected.
2. No power at outlet.

3. Tool’s thermal reset breaker

tripped (if equipped).

4. Internal damage or wear.

(Carbon brushes or switch,

for example.)

1. Check that cord is plugged in.
2. Check power at outlet. If outlet is unpowered,

turn off tool and check circuit breaker.

If breaker is tripped, make sure circuit is right

capacity for tool and circuit has no other loads.

3. Turn off tool and allow to cool.

Press reset button on tool.

4. Have technician service tool.

Tool operates slowly. Extension cord too long or

wire size too small.

Eliminate use of extension cord. If an extension

cord is needed, use shorter/heavier gauge cord.

See Extension Cords in GROUNDING section.

Performance

decreases over time.

Carbon brushes worn or damaged. Have qualified technician replace brushes.

Excessive noise

or rattling.

Internal damage or wear. (Carbon

brushes or bearings, for example.)

Have technician service tool.

Overheating.

1. Forcing machine to work too fast.
2. Accessory misaligned.

3. Blocked motor housing vents.

4. Motor being strained by long or

small diameter extension cord.

1. Allow machine to work at its own rate.
2. Check and correct accessory to

fence and/or table alignment.

3. Wear ANSI-approved safety goggles and NIOSH-

approved dust mask/respirator while blowing

dust out of motor using compressed air.

4. Eliminate use of extension cord.

If an extension cord is needed, use one with

the proper diameter for its length and load.

See Extension Cords in GROUNDING section.

Follow all safety precautions whenever diagnosing or servicing the tool.

Disconnect power supply before service.