Rack Installation Guide

Flush-Mount Installation

The two-post rack kit is shipped with the brackets configured for a 7.62-cm (3-inch) wide center-
mount installation. See Figure 1-9 for mounting rail components. To prepare the mounting rails for
flush-mount installation in the two-post rack, perform the following steps:

1

Locate the two mounting rails and place them side by side on a smooth work surface, with the
front ends of the mounting rails toward you (see Figure 1-13).

2

Using a 3/8-inch wrench or nut driver, remove two nuts from the adjustable mounting bracket
(see Figure 1-13).

3

Remove the bracket and then place the bracket on either the 7.62-cm or 15.24-cm (3-inch
or 6-inch) wide flush-mount threaded studs (see Figure 1-13).

4

Using the two nuts that you removed in step 2, tighten the nuts finger tight to secure
the adjustable mounting bracket (see Figure 1-13).

5

Repeat step 2 through step 4 to configure the other mounting rail.

Figure 1-13.

Configuring the Adjustable Mounting Bracket for Flush-Mount Installation

nuts (2 per bracket)

flush-mount
mounting flange

7.62-cm (3-inch) wide, flush-mount, threaded studs

adjustable mounting bracket