Installation to a high ceiling, Preparation, Make a hole in the ceiling – Canon RS-CL07 User Manual
Page 21: Secure the ceiling-mount bracket to the ceiling, Attach the base bracket to the projector, Attach the anti-fall wires
Mounting hole position
Distance from ceiling to lens axis (l)
RS-CL08
RS-CL09
a
60 cm/2.0'
80 cm/2.6'
b
65 cm/2.1'
85 cm/2.8'
c
70 cm/2.3'
90 cm/3.0'
d
75 cm/2.5'
95 cm/3.1'
e
80 cm/2.6'*
100 cm/3.3'
f
105 cm/3.4'
g
110 cm/3.6'
h
115 cm/3.8'
i
120 cm/3.9'*
Preparation:
Adjust the pipe length according to
the ceiling height
1 Remove the covers of outer and inner
pipes by slightly sliding them and lift up
as shown.
2 Remove four M5 screws from the
sides of the outer pipe, adjust the inner
pipe length according to the projector
installation height, and then secure the
four M5 screws.
● When attaching screws in step 2, insert the
screws and leave an unused screw hole
between them. When the extension pipe is
stretched to its maximum length, insert the
screws in two adjacent screw holes.
Installation to a High Ceiling
Use optional extension pipe RS-CL08 or RS-CL09 for high ceiling.
1
2
Pipe extension length
f
a
b
c
e
g
d
h
l
* To use the extension pipe with it extended to the maximum length, secure it by inserting
screws in the two adjacent screw holes.
l' = 4.1 cm/0.14' (WUX10 MarkII/SX7 MarkII/SX60/X700) /4.5 cm/0.15' (SX80 MarkII/SX800)
i
l'
1
Separate the Joint fitting from the
Ceiling-mount bracket temporarily
2
Make a hole in the ceiling
3
Secure the Ceiling-mount bracket to
the ceiling
4
Attach the Base bracket to the
projector
5
Attach the anti-fall wires