Installation guide, Warning, For: uni–red, uni–green, and uni–ir – LaserMax LMS-UNI-MAX GREEN User Manual
Page 2
For Rifle Pack Owners:
Aligning the Laser
Limited Warranty
1 | To sight in your laser, insert the
adjustment tool into one of the
small alignment ports on the
outside of the laser housing.
2 | Fine tune your laser alignment
by slowly turning the adjustment
tool, then checking your laser
position against your fixed sights
and your point of impact (POI).
IMPORTANT: This alignment
should be done at a minimum
distance of 10 yards. A ¼ turn
equals approximately three inches
at ten yards.
Warning: Do not turn the
adjustment tool more than
one complete turn from factory
position. This may cause
damage to the laser and may
void your warranty.
The hole at the bottom adjusts
elevation (vertical alignment). A
clockwise turn (left side, to front,
to right side of firearm) shifts laser
down. The hole on the side
adjusts windage (horizontal
alignment). A clockwise turn
(front, to top, to bottom) shifts the
laser to the left.
Registration of your product is required in order
to receive warranty service. Go to lasermax.com/
Service/RegisterWarranty.aspx to fill out the
registration form.
The product that you have purchased is subject to the
terms of this limited warranty. This limited warranty
gives you specific legal rights, and you may also have
other rights, which vary from State to State. The product
you purchased is warranted to be free from defects in
material
and workmanship at the time of purchase.
This limited warranty does not cover expendable parts
(i.e. batteries), because they have definite and predictable
life expectancies and should be replaced by you, to
protect the product and preserve your warranty. This
limited warranty also does not cover damages due
to equipment or parts, which upon inspection are
determined by LaserMax to have become defective after
the date of purchase due to abuse, misuse, etc. The
coverage of this limited warranty begins on the date of
purchase and ends 5 years after the date of purchase.
This limited warranty is extended only to the original
purchaser of the product and is not transferable. To
be eligible for warranty coverage you as the original
purchaser of the product must register the product in
our warranty registration system at www.lasermax.com
within 90 days of your original purchase.
To make a warranty claim you must make a warranty
repair request no later than the date that is five (5)
years from the date of purchase and obtain a return
authorization number from our Warranty Department at
1-800-LASER-03.
Once you have made a warranty claim, LaserMax will
inspect the product to determine whether it is eligible
for warranty coverage. If eligible, LaserMax will repair
or replace the part(s)/product that LaserMax, in its
sole discretion, determines to be defective during the
warranty period. If not eligible, LaserMax will return the
part(s)/product to you and inform you why coverage is
not available. LaserMax reserves the right to substitute
equivalent product replacement at its discretion.
Any and all implied warranties, including the implied
warranties of merchantability, fitness for a particular
purpose, and non-infringement also begin on the date
of purchase and end five years after the date of purchase.
Some States do not allow limitations on how long an
implied warranty lasts, so the above limitation may not
apply to you. The foregoing is your exclusive remedy
and LaserMax’ exclusive liability for any warranty claim.
LaserMax will not, under any circumstances, be liable
for any incidental, indirect, consequential, punitive or
exemplary damages (even if LaserMax has been notified
of the possibility of such damages) resulting from or
related to a product including, without limitation, any
loss of profits, or loss of opportunity, or damages in
excess of your purchase price for the product. Some
States do not allow the exclusion or limitation of
incidental or consequential damages, so the above
limitation or exclusion may not apply to you.
For: UNI–RED, UNI–GREEN, and UNI–IR
Installation Guide
Warning
Red and Green Lasers
CLASS 3R VISIBLE LASER
Output Power: <5mW
Wavelength: 500 —700nm
Infrared Laser
CLASS 1 INVISIBLE LASER
Output Power: <0.7mW
Wavelength:
850nm
LaserMax, Inc.
3495 Winton Place
Rochester, NY 14623 USA
1 | Using a Phillips head
screwdriver, remove battery
cover (figure G).
2 | Remove slide switch housing
screws (figure G) and gently
remove activation switch to
reveal switch contact pins
(figure H). Store activation
switch and cover for future use.
3 | Align slide switch housing of
momentary activation switch
with rear of Uni-Max (figure I)
and insert slide switch housing
screws (figure J). Turn clockwise
to gently tighten until resistance
is felt. Do not over tighten.
4 | Replace battery cover and
battery cover screws (figure K).
5 | Fasten the Uni-Max to the rail of
firearm. Locate the activation
switch pad.
6 | Insert pressure pad through
front of Manta end cap (figure L).
7 | Before inserting into Manta
Rail, coat pressure pad with
a small amount of supplied
lubricant to assist in installation.
8 | Insert pressure pad (top side up)
into the Manta Rail panel and
adjust to desired position
(figure M).
If multiple Manta Rail panels
are used: insert pressure pad
and wire through panels that
are positioned in line prior to
placement.
9 | Attach additional Manta
End Cap on opposite end of the
MantaRail panel and push
together until flush (figure N).
10 | Position bottom edge of Manta
Rail assembly against edge of
the firearm rail. Snap the Manta
Rail down over the opposite
edge.
11 | Push Manta end caps inward to
ensure proper fit and alignment.
12 | Use supplied Manta clips to
secure cord flush with the rail
to ensure snag-free operation
(figure O).
13 | Move the small white slide
switch (located on slide switch
housing) to the forward position
to initiate activation switch pad
operation (figure P).
14 | With slide switch in the forward
position, the Uni-Max laser will
turn on whenever the activation
switch pad is depressed.
Releasing the activation switch
pad will turn the laser off.
Note: Switch in the forward
position, toward cord, is active
(figure P). Switch in the rear
position, away from cord, is
inactive.
L
M
N
O
G
I
K
H
J
P
Installing the LaserMax Momentary Switch and Manta Rail System