beautypg.com

9accessories available from denex, 1 conversion kits – Baumer BA DenexGripperLED User Manual

Page 16

background image

User Manual DENEX Gripper LED

16/24

Baumer Electric AG

Version 2013-02, V1.4

www.baumer.com

Frauenfeld, Switzerland

9

ACCESSORIES AVAILABLE FROM DENEX

There are a number of accessories available from Baumer that can save you time and
ensure a good operation of the sensor. Kits for replacing mechanical or older sensors are
available. See web site

www.baumer.com

or

www.denex.com

for more updated

information.

9.1 Conversion kits

Order a Ferag Finger to Gripper LED Conversion Kit from Baumer to make the installation
quick and easy.
For TTR: Part. No. 11084181 (formerly 51G6040) or
For UTR: Part. No.11084159 (formerly 51G6050)
Full instruction is included in the kit containing bracket and cable.

9.1.1 Exchanging Ferag-Finger with Baumer proximity switch

Check the type (NPN or PNP) of Ferag-Finger that is used.
Check the type (NPN or PNP) of Baumer that is used.
Wire according to chapter 5.

If the output is inactive (0V on the output) when no papers are present and the Baumer

is inactive when no Gripper is close to it Use Mode 2.

If the output is active (LED is ON at the Finger) when no papers are present and the

Baumer is inactive when no Gripper is close to it Use Mode 3.

If the output is inactive (0V on the output) when no papers are present and the Baumer

is active when no Gripper is close to it Use Mode 4.

If the output is active (LED is ON at the finger) when no papers are present and the

Baumer is active when no Gripper is close to it Use Mode 5.


Wire the DENEX Gripper LED Output Cable either for current source or current sink,
depending on the Ferag input stage.