beautypg.com

Baumer VisiLine cameras User Manual

Page 2

background image

LED Signaling

1

2

LED

Signal

Meaning

1

green

Link active

green flash

Receiving

2

yellow

Transmitting

Installation

Installation of the camera:

Connect the camera using an

appropriate cable (at least Cat-5e)

to he GigE board on your PC.

If required, connect a trig-

ger and / or flash to process

interface.

Connect the camera to power supply.

Installation of cameras with PoE:

Connect the camera using an appropriate cable (at least Cat-5e) to a free port of a

PoE capable ethernet switch.
Establish the connection between switch and GigE board on your PC.

If required, connect a trigger and or flash to process interface.

Data Interface / Power Supply / Digital IOs

Notice

The VisiLine supports PoE (Power over Ethernet) IEEE 802.3af Clause 33, 48 V

power supply.

8P8C mod jack with LEDs

1

8

1

green/white

MX1+

(negative / positive V

port

)

2

green

MX1-

(negative / positive V

port

)

3

orange/white

MX2+

(positive / negative V

port

)

4

blue

MX3+

5

blue/white

MX3-

6

orange

MX2-

(positive / negative V

port

)

7

brown/white

MX4+

8

brown

MX4-

Power supply / Digital-IO

wire colors of the connecting cable

1

4

5

6

3

2

3

4

1

1

Power V

CC

brown

1

not used

brown

2

IN 1

white

3

OUT 2

blue

3

GND

blue

4

OUT 3

black

4

OUT 1

black

Notice

The electrical data are available in he

respective data sheet.

5

U

ext

OUT

grey

6

GND IN

pink

Installation sample

1 - PCI board; 2 - GigE cable;

3 - Power cable / Digital-IO; 4 - Digital-IO

Installation sample

1 - PCI board;

2 - GigE cable;

3 - PoE capable ethernet switch

or Baumer PoE components;

4 - Cable for trigger and flash

open wire

Heat Transmission

Caution

Heat can damage the camera. Provide adequate dissipation of heat,

to ensure that the temperature does not exceed

he value in the table

below.

As there are numerous possibilities for installation, Baumer does not

specify a specific method for proper heat dissipation.

T

Measure Point

Maximal Temperature

T

50°C (122°F)

General Description

1

2

3

4

No.

Description

No.

Description

1

C-Mount lens connection

4

Power supply / Digital-IO

2

Ethernet Port

3

Digital-IO

open wire