beautypg.com

Citizen Systems iDP3423 User Manual

Page 39

background image

iDP3420/3421/3423 User’s Manual

23

CITIZEN

2) DIP Switch 2

No.

Function

ON

OFF

Factory Setting

DS2-1

Bit length

8 bits

7 bits

ON

DS2-2

Parity

No

Yes

ON

DS2-3

Odd/Even

Odd

Even

ON

DS2-4

Communication mode

DTR/DSR

XON/XOFF

ON

DS2-5

Baud rate

ON

DS2-6

ON

DS2-7

See the table below

OFF

DS2-8

Unused

OFF

Baud rate

Baud rate

DS2-5

DS2-6

DS2-7

150

OFF

OFF

OFF

300

OFF

OFF

ON

600

OFF

ON

OFF

1200

OFF

ON

ON

2400

ON

OFF

OFF

4800

ON

OFF

ON

9600

ON

ON

OFF

19200

ON

ON

ON

The DIP switch 2 is used only for the serial interface.

(Note) Setting of the paper used simply changes the drive pulse width to the printing head; it does not

mean that 2-ply paper is not available for the 1-ply setting.

The same applies to when 1-ply

paper is used for the 2-ply setting.