5data sheet – Baumer BA Scatec2 Gripper User Manual
Page 10

20101215_Shortmanual_ScatecDCC_EN.doc
10/10
Baumer Electric AG
15.12.2010 / wej
Frauenfeld, Switzerland
5
Data sheet
SCATEC – double copy counter
FLDK 110G1903/S42
Dimension drawing
Photo
General data
Measuring distance sd
0 … 120 mm
Optimum operating distance
70 mm
Object speed
< 5 m/sec
Sensitivity
Single sheet / edge thickness
0.25 mm
Synch. Input
Yes
Measuring point
Visible red laser line 2 mm
Light source
Pulsed red laser diode
Wave length
650 nm
Laser class
2
Edge indicator
LED yellow
Power on indicator
LED green
Electrical data
Voltage supply range +Vs
10 … 30 VDC
Power consumption
< 2 W
Output circuit
2 x push pull
Short circuit protection
Yes
Reverse polarity protection
Yes
Synch. Input
PNP
Mechanical data
Type
Rectangular
Housing material
PA 6
Connector base
DIN 45326, 8 pin and M8
Front (optics)
glass
Ambient conditions
Operating temperature
0 … +50°C
Protection class
IP 54
Connection diagram
1 synch. +
2 voltage supply +Vs
3 serial interface TxD
4 GND (for synch.)
5 serial interface RxD
6 output 1
7 GND
8 output 2
Connector M16 / S42
Connector M8 / S35
1 voltage supply +Vs
3 GND
4 synch. +