Removing bypass/servo, Fig. 6 fig. 7 – FLO~PRO 301008 User Manual
Page 6

STEP 9:
Now that you've removed the heat shield,
remove the four 10mm bolts holding the
exhaust bypass in place. The bypass will be
removed with the servo in the next steps.
STEP 10:
Remove the five 10mm bolts securing the
EGR servo mounting bracket in place.
Simultaneously remove the EGR servo & the
exhaust bypass from the vehicle. (Fig. 6)
STEP 11:
Remove the crankcase breather tube that
runs over the EGR cooler. Also, disconnect
the two coolant lines that run to the EGR
cooler. Be sure to remove the O-Ring fitting
from the engine block. (Fig. 7) Remove the
four 10mm EGR cooler mounting bolts
(Circled Fig. 7).
STEP 12:
Remove the two 15mm nuts connecting to the
EGR cooler to the exhaust manifold near the
fire wall.
Removing Bypass/Servo
Fig. 6
Fig. 7
Bypass
Servo
Coolant Lines