Do Not use sealant on AN (Male Flare) fittings. Only use sealant on threads installed into pump assembly.

A.

Route suction line from the suction tube assembly to the ’T’ port on
the FASS pump. Cut the fuel line and insert PL-1005 using oil. At-
tach to 10-300 in ‘T’ port. Torque to 18 lb./ft.²

C.

Insert PL-1005 into fuel line using oil. Attach to 10-300 located in
the port labeled ‘E’.. Torque to 18 lb./ft.² Route this line to the en-
gine side of the factory lift pump.

B.

Install in-line fuel filter in an accessible location in the suction line
using the HC-1001’s. Make sure the arrow is in the direction of the
fuel flow. .

D.

Disconnect factory power to the lift pump. Drain fuel from factory
lift pump.

E.

Disconnect the yellow-clipped factory feed at the factory lift pump.
Refer to diagram at the beginning of Step 2.

Note: Inline filter will need to be replaced every 6,000 miles.