beautypg.com

Planning the installation – EcoPure EPASF1 User Manual

Page 5

background image

5

ALWAYS INSTALL THE FILTER UPRIGHT

To operate properly, the Automatic Sediment Filter

must be installed with the sump pointed straight down.

When possible, install the filter on a horizontal section

of the household’s main incoming water pipe. If the

available incoming main house water pipe runs verti-

cally where you want to install the filter, buy 90° pipe

elbows and plumb a detour, as shown in Figure 4.

Allow enough space under the filter (6” minimum) to

remove the sump (to clean or replace the filter screen).

Allow enough space above the filter to remove the top

cover (to change batteries, etc.), as shown in Figure 4.

REVERSING THE FACEPLATE / DISPLAY

The Automatic Sediment Filter must be installed with

the water flowing into the side of the filter marked IN.

Remove the unit’s top cover and observe the IN and

OUT markings. Depending on the direction of water

flow and the viewing angle, the faceplate may need to

be reversed (turned around to face the opposite direc-

tion) so that it does not end up against a wall or other

obstruction. This can be done either before or after

the filter is installed on the plumbing:
1. Remove the top cover from the ASF by sliding it

upward.

2. With a phillips screwdriver, remove the 2 screws

holding the faceplate assembly to the filter head

(See Figure 5).

3. Lift the faceplate assembly up and turn it around

180°, taking care not to pull on the wires between

the electronic control board and the valve solenoid.

4. Lower the faceplate assembly into place on the

opposite side of the head and reinstall the 2 screws.

5. Slide the top cover back onto the ASF and push it

down to snap into place.

MOUNTING BRACKET

A metal bracket is included with the Automatic

Sediment Filter to support the assembled filter and

plumbing when necessary. It may be mounted to a

wall or wall framing member with 2 screws (included),

as shown in Figure 6.
The 2 mounting bracket screws should be installed

before the filter is installed on the plumbing. When

installing the plumbing, be sure to put the bracket in

position around the ASF before installing inlet and out-

let fittings. The bracket can not be put on after the

inlet and outlet fittings are installed.

Planning the Installation

FIG. 4

FIG. 6

FIG. 5

10"

min.

6”

min.

IN

OUT

10”

min.

House Water

Supply Pipe

Sump

Pointed

Straight

Down

3"

Mounting

Bracket

Remove 2

screws and

turn faceplate

around, if

necessary