beautypg.com

Electronic controller (continued) – EcoPure EPASF1 User Manual

Page 12

background image

12

LED blinking

red every 8

sec. indicates

battery is low

“E E” in the

display indi-

cates battery

is low

3. Take a new 9-volt battery and snap the battery con-

nector onto both terminals.

4. Place the connected battery into the clip provided

for it directly above the IN port (See Figure 18 on

Page 10).

5. Slide the top cover back onto the ASF and push it

down to snap into place.

No reprogramming of the controller is necessary after

battery replacement or a power outage.

Electronic Controller (continued)

FIG. 23

The ASF controller is shipped with a default value of 7

days between automatic sediment flushes. To change

the number of days (between 1 and 30) or to turn this

feature off:
1. Press the PROGRAM button and hold it for at least

2 seconds. When the LED turns on steadily with an

amber color, quickly release the PROGRAM button.

2. While the amber LED is on (it turns off after 10 sec-

onds of button inactivity), repeatedly press the PRO-

GRAM button until the desired number of days

shows in the display. Each press increases the

number of days by 1. When the number passes 30,

it returns to zero, indicated by “- -”, and counts up

from 1 again.

3. Setting the number of days to “- -” (zero) turns off

the automatic flush feature.

4. When the desired number of days shows in the dis-

play, wait 10 seconds (press no more buttons) for

the amber LED to go off. The new number of days

is programmed. This new setting will remain after

battery change or power loss.

TIME OF DAY WHEN FLUSH OCCURS

The time of day when the automatic sediment flush will

occur is the same time of day as when the most recent

of the following was done:

=

The filter was powered up (battery installed or

replaced, optional AC adaptor plugged in)

=

The number of days was set

=

A manual flush was initiated

If a different time of day is desired for automatic flush,

simply initiate a manual flush (as described on the pre-

vious page) at the desired time of day.

LOW BATTERY INDICATION

If the LED is blinking red every 8 seconds (and the 2-

digit display shows “E E“), then the battery needs to be

replaced.

BATTERY REPLACEMENT

1. Remove the top cover from the ASF by sliding it

upward (See Figure 18 on Page 10).

2. Locate the old battery and unsnap it from the bat-

tery connector. Dispose of (recycle) old battery

properly.

FIG. 22

SETTING THE NUMBER OF DAYS BE TWEEN

AUTOMATIC SEDIMENT FLUSHES

Two dashes

(not moving)

in the display

indicate auto-

matic flush is

turned off