beautypg.com

Terminal connections and dimensions, 4 specifications, 3 terminal connections and dimensions – Dynalco DST-2000C Direction Sensing Tachometer User Manual

Page 6

background image

6

DST-2000C Instruction Manual

1.3

Terminal Connections and Dimensions

Figure 1-1 Outline Drawing

1.4 Specifications

Input Signal:

Signal from Dynalco M343 dual output magnetic pickup only.
Frequency range 0.5 Hz to 20 kHz.

Signal Amplitude:

25 mVrms minimum; 15 Vrms maximum.

115 Vac and/or 12 Vdc (standard)*
115 Vac and/or 24 Vdc (optional)*
230 Vac and/or 12 Vdc (optional)*
230 Vac and/or 24 Vdc (optional)*

Input Power:



*+10%, 50/60 Hz, +10%, 2 watts maximum

Input Current:

2 watts, maximum.

Operating Temperature:

–30

o

F to +160

o

F (–34

o

C to +71

o

C)

Output Relays:

Two SPDT relays. Contact rated 5 A, resistive, 115 Vac.

Remote LED Outputs:

Two 10 mA nominal outputs.

Directional Output
Pulses:

Two outputs: one for CW, one for CCW. Pulses are 0 to +8 V,
35 microseconds nominal width.

Speed Signal Output:

Proportional to input frequency. Square wave 8 V peak-to-peak.

Meter Output:

0–1 mA analog output proportional to input frequency.

Auxiliary Output Supply:

Regulated +8 Vdc (25mA).