1.3
Terminal Connections and Dimensions
Figure 1-1 Outline Drawing
1.4 Specifications
Input Signal:
Signal from Dynalco M343 dual output magnetic pickup only.
Frequency range 0.5 Hz to 20 kHz.
Signal Amplitude:
25 mVrms minimum; 15 Vrms maximum.
115 Vac and/or 12 Vdc (standard)*
115 Vac and/or 24 Vdc (optional)*
230 Vac and/or 12 Vdc (optional)*
230 Vac and/or 24 Vdc (optional)*
Input Power:
*+10%, 50/60 Hz, +10%, 2 watts maximum
Input Current:
2 watts, maximum.
Operating Temperature:
–30
o
F to +160
o
F (–34
o
C to +71
o
C)
Output Relays:
Two SPDT relays. Contact rated 5 A, resistive, 115 Vac.
Remote LED Outputs:
Two 10 mA nominal outputs.
Directional Output
Pulses:
Two outputs: one for CW, one for CCW. Pulses are 0 to +8 V,
35 microseconds nominal width.
Speed Signal Output:
Proportional to input frequency. Square wave 8 V peak-to-peak.
Meter Output:
0–1 mA analog output proportional to input frequency.
Auxiliary Output Supply:
Regulated +8 Vdc (25mA).