beautypg.com

Dynalco LST-100L Tachometer User Manual

Calibration instructions

background image

QUICK

GATE TIME

CALCULATION

See label on back of LST-100, LST-100L for additional information

If necessary, turn to the reverse side of the card
to calculate Signal Frequency and Gate Time.

LST-100 and LST-100L

SELF-POWERED TACHOMETER

Calibration Instructions

The LST-100 and LST-100L tachometers are normally factory-
calibrated to the customer-specified number of sensing teeth or
discontinuities, sensing speed, and desired numerical display.

}

Assumes the pickup is “seeing” the
gear of interest directly, not through
a step up or step down ratio

.

{

Example:

If 3390 Hz = 1800 RPM, then gate time is 0.53 seconds.

1. Apply 3390 Hz to terminals A and B on tachometer (no polarity).
2. Turn the gate time range switch to (either) position number 1 to

select gate time range of 0.26 – 0.72 seconds.

3. Adjust the vernier potentiometer to obtain a display of 1800.

60

Number of

Teeth

To calibrate the LST-100 or LST-100L:

1. Remove the sealing plug on the back of the housing.

2. Apply the calculated signal frequency to terminals A and B.

A Dynalco F-16 or F-15 signal generator is ideal.

3. Select the appropriate gate time range on the 4-position

switch.

See label on back of LST-100; LST-100L; or Item 3, reverse

side of card.

4. Adjust the vernier potentiometer for the desired display.

See below

.

(For example: 60 /113 teeth = 0.53 sec. gate time)

Shown with sealing plug removed

Vernier potentiometer

[clockwise to increase display reading;
counterclockwise to decrease]

4-position switch

This manual is related to the following products: