beautypg.com

Checkout procedures – Crown Audio 800CSL User Manual

Page 16

background image

Power Base-2 & 800CSL Amplifier Service Manual

16

Checkout Procedures

POST TESTING

After completion of testing, if all tests are satisfactory,
the amplifier controls should be returned to the posi-
tions required by customer. If conditions are unknown
or unspecified, factory settings are as follows:
Level Controls: 9 to 11 O’Clock.
Sensitivity Switch: 0.775V U.S., 1.4V International.
Stereo/Mono Switch: Stereo.
Ground Lift: Lift.
Power: Off.