Step 3

Setup Sprinkler Controller and Set Cycle Window

2. The cycle window is the time allowed to complete a watering cycle once the first zone has

started watering. The S100 comes preset with a 12 hour window. Adjust this value to be at

least one hour more than your complete cycle time.

Reasons to re-set the cycle window

:

● If your system needs more than twelve hours to complete a watering cycle once the

cycle has started.

● If you choose to water your lawn several times per day (this can result in poor root

development).

To set the cycle window hold the “Bypass” button for 2 seconds. This will display the current

cycle window. Use (+)/(-) buttons while holding the “Bypass” button to change the cycle

window to a value between 0 and 24 hours. When the cycle window is finished, and the

moisture is still below the threshold, the cycle window will start again if a valve is running. It

is important the cycle window is set to fit all watering needs plus an additional hour for

padding.

7

WaterTec S100 Manual June08

Step 4

Connect the biSensor

NOTE: It is very important that you use waterproof connectors after all connections

have been verified in Step 7.

1. Before burying the biSensor, verify communications by pressing the “Read / Set” button.

A numeric reading indicates success. A display of Er1 or Er2 indicates a wiring error.

Consult the Troubleshooting section on pages 11-12.

2. Manually run the station to which you connected the biSensor to verify connection.

3. Once connections have been verified, disconnect the biSensor from the valve as this

simplifies burial.

Soil Moisture

Moisture Threshold/

Cycle Window

BYPASS

READ / SET

DRY /

ALLOW

BUSY

*

%

+

WETTER

-

DRYER

MADE IN USA

Soil Moisture Sensor

WaterTec

TM

S100

Soil Moisture

24V

COM

1 2 3 4 5 6 7 8

SPRINKLER TIMER

Connect sensor wires across valve solenoid.

1. Set your sprinkler controller to apply

1/2” to 3/4” of water to each zone each

day. This will allow the in-ground

moisture biSensor to choose the best

possible days to water. For instructions

on how to check distribution rate, see

STEP 2 on page 15 of the

Troubleshooting section. (If needed,

refer to the sprinkler timer’s manual for

operational instructions).