Operational troubleshooting & adjustments – Baseline Systems WaterTec S100 User Manual

Page 13

background image

12

WaterTec S100 Manual June08

Operational Troubleshooting & Adjustments

Main Problem

Specifics

Solution

● Check the wiring and connections to the biSensor
● Connections need to be waterproof and free of corrosion
● Check biSensor wires for damage
● Check biSensor for damage
● After making repairs follow the "Verify biSensor
Communication" instructions under Step 1 at the end of this
section

Double-check the wiring and connections to the biSensor

● Verify connections inside the valve box are tight
● Check for a faulty valve solenoid
● Check for lightning damage

● Make sure the 24 VAC transformer is plugged in and
receiving power

● Check that the 24VAC line and the common line from the
S100 are wired correctly

There are puddles
forming during
irrigation

● Follow the instructions under Step 6 at the end of this
section

Er2 is displayed

The S100 has detected excessive
current while trying to communicate
with the biSensor

Display is blank.
LED's are off

S100 is not receiving 24 VAC

Er1 is displayed

The S100 cannot communicate with
the biSensor

Er3 is displayed

Moisture Sensor is damaged

● Replace moisture sensor